Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Psychiatry Res Neuroimaging ; 328: 111580, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36481591

RESUMO

Corpus callosum (CC) is the largest commissural white matter bundle in the brain, responsible for the integration of information between hemispheres. Reduction in the size of the CC structure has been predominantly reported in children with autism spectrum disorder (ASD) compared to typically developing children (TD). However, most of these studies are based on high-functioning individuals with ASD but not on an inclusive sample of individuals with ASD with varying abilities. Our current study aimed to examine the CC morphometry between children with ASD and TD in the Indian population. We also compared CC morphometry in autistic children with autism severity, verbal IQ (VIQ) and full-scale IQ (FSIQ). T1-weighted structural images were acquired using a 3T MRI scanner to examine the CC measures in 62 ASD and 17 TD children. The length and height of the CC and the width of genu were decreased in children with ASD compared to TD. There was no significant difference in CC measures based on autism severity, VIQ or FSIQ among children with ASD. To our knowledge, this is the first neuroimaging study to include a significant number (n = 56) of low-functioning ASD children. Our findings suggest the atypical interhemispheric connectivity of CC in ASD.


Assuntos
Transtorno do Espectro Autista , Transtorno Autístico , Substância Branca , Humanos , Criança , Corpo Caloso/diagnóstico por imagem , Transtorno Autístico/diagnóstico por imagem , Transtorno do Espectro Autista/diagnóstico por imagem , Encéfalo , Substância Branca/diagnóstico por imagem
2.
Haemophilia ; 27(3): 488-493, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33780101

RESUMO

OBJECTIVES: Early detection of bleeding into a joint is crucial in patients with haemophilia. This study was designed to evaluate the sensitivity of ultrasonography (USG) and magnetic resonance imaging (MRI) to detect the presence of blood in small concentrations in a simulated model to mimic joint bleeding. MATERIALS AND METHODS: Different concentrations of blood in plasma, varying from 0.1% to 45%, were collected in 10-ml plastic syringes and imaged using 12 and 18 MHz USG transducers and with 1.5T and 3T MRI scanners, at different intervals of time following dilution. The images were scored for the presence of blood by four experienced radiologists who were blinded to the concentration of blood. RESULTS: Within the first 2 h, the 18 MHz transducer was able to detect blood consistently up to 0.5%, whereas the 12 MHz transducer could consistently identify blood up to 1.4%. After the first 12 h, both transducers were able to detect blood up to 0.5% concentration. However, at concentrations below 0.5%, there was discordance in the ability to detect blood, with both transducers. There was no correlation between the signal intensities of MRI images and concentration of blood, at different time intervals, irrespective of the magnetic field strength. CONCLUSIONS: Detection of blood using the USG is dependent on variables such as the concentration of blood, frequency of the transducer used and timing of the imaging. As the concentration of blood decreases below 0.5%, the discordance between the observers increases, implying that the detection limit of USG affects its reliability at lower concentrations of blood. Caution is urged while interpreting USG imaging studies for the detection of blood in symptomatic joints.


Assuntos
Hemartrose , Hemofilia A , Hemofilia A/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Ultrassonografia
3.
J Med Phys ; 46(4): 295-299, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35261499

RESUMO

Purpose: Ionizing radiation has been extensively used for medical diagnosis since its discovery in 1895; however, excessive use can lead to deleterious effects. Prior knowledge on radiological protocols based on simulations would be a practical tool for optimal use of radiation. Materials and Methods: Scan length of the thorax was measured from computed tomography (CT) topographic images and cross-sections at three levels of the thorax were measured from tomographic images of 500 adults and 340 children who had undergone CT thorax examinations using Centricity workstation software. The effective diameter (ED) of the thorax was calculated from anterio-posterior (AP) and transverse anatomical dimensions. Results: A 17% increase in scan length was observed for 6-10 years age group compared to 0-5 years, whereas there was marginal increase for 11-15 years of age. A 11.5% increase was observed for 16-18 years compared to 11-15 years age group. The cross-sectional phantom dimensions were calculated from ED measurements obtained from three regions of the thorax. Conclusions: This study has provided age- and gender-specific reference scan lengths, AP and transverse dimensions and ED for radiological examinations of the thorax. This information is useful to develop age- and gender-specific preset protocols and fabricate phantoms of the thorax for the pediatric and adult Indian population.

4.
Indian J Radiol Imaging ; 29(3): 247-252, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31741591

RESUMO

BACKGROUND: Fluoroscopy-guided interventions can potentially increase radiation risk to patients, if awareness on angiographic imaging technique and radiation dose is neglected. AIM: To develop patient radiation dose reference card from standardized imaging techniques for various radiology interventions performed using flat detector based angiography system. MATERIALS AND METHODS: Real-time monitoring of angiographic exposure parameters and radiation dose were performed for 16 types of radiological interventions. Effective dose (ED) was estimated from dose area product (DAP) using PCXMC Monte Carlo simulation software. Radiation risk levels were estimated based on Biological Effects of Ionising radiation (BEIR) report VII predictive models for an Asian population. RESULTS: Pulse rates of 7.5 pps and 0.6 mm Copper filtration during fluoroscopy and 4 frames per second (fps) and 0.1-0.3 mm Cu filtration during image acquisitions were found to reduce radiation dose. Owing to increased number of image acquisitions, DAP was highest during diagnostic spinal angiography 186.7 Gycm2 (44.0-377.5). This resulted in highest ED of 59.4 mSv with moderate risk levels (1 in 1000 to 1 in 500). Most of the radiological interventions had low radiation risk levels (1 in 10,000 to 1 in 1000). CONCLUSION: The patient radiation dose reference card is valuable to the medical community and can aid in patient counselling on radiation induced risk from radiological interventions.

5.
Indian J Radiol Imaging ; 28(2): 258-262, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30050253

RESUMO

BACKGROUND: Protective lead or lead-equivalent (Pbeq) aprons play a key role in providing necessary shielding from secondary radiation to occupational workers. Knowledge on the integrity of these shielding apparels during purchase is necessary to maintain adequate radiation safety. AIM: The aim of the study was to evaluate the lead equivalence in aprons based on simple quality assessment tool. MATERIALS AND METHODS: 0.25 mm and 0.5 mm lead and lead-free aprons from 6 manufacturers were assessed using a calibrated digital X-ray unit. The percentage attenuation values of the aprons were determined at 100 kVp using an ionization chamber and the pixel intensities were analyzed using digital radiographic images of lead apron, copper step wedge tool, and 2 mm thick lead. RESULTS: Mean radiation attenuation of 90% and 97% was achieved in 0.25 mm and 0.5 mm lead or lead-free aprons respectively. The pixel intensities from 0.25 mm Pbeq apron correspond to 0.8-1.2 mm thickness of Cu while 0.5 mm Pbeq aprons correspond to 2.0-2.8 mm of Cu. CONCLUSION: Pixel intensity increased with increase in the thickness of copper step wedge indicating a corresponding increase in lead equivalence in aprons. It is suggestive that aprons should be screened for its integrity from the time of purchase using computed tomography (CT), fluoroscopy, or radiography. It is recommended that this simple test tool could be used for checking lead equivalence if any variation in contrast is seen in the image during screening.

6.
J Radiol Prot ; 38(2): 511-524, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29380743

RESUMO

The radiation dose from complex cardiac procedures is of concern due to the lengthy fluoroscopic screening time and vessel complexities. This study intends to assess radiation dose based on angiographic projection and vessel complexities for clinical protocols used in the performance of percutaneous transluminal coronary angioplasty (PTCA). Dose-area product (DAP), reference air kerma (K a,r) and real-time monitoring of tube potentials and tube current for each angiographic projection and dose setting were evaluated for 66 patients who underwent PTCA using a flat detector system. The mean DAP and cumulative K a,r were 32.71 Gy cm2 (0.57 Gy), 51.24 Gy cm2 (0.9 Gy) and 102.03 Gy cm2 (1.77 Gy) for single-, double- and triple-vessel PTCA, respectively. Among commonly used angiographic projections, left anterior oblique 45°-caudal 35° reached 2 Gy in 55 min using a low-dose fluoroscopy setting and 21 min for a medium-dose setting. Use of a low-dose setting for fluoroscopic screening showed a radiation dose reduction of 39% compared with a medium-dose setting.


Assuntos
Angioplastia Coronária com Balão , Angiografia Coronária , Doses de Radiação , Adulto , Idoso , Angioplastia Coronária com Balão/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
J Radiol Prot ; 37(4): 927-937, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28885191

RESUMO

The purpose of the study was to measure radiation doses and estimate risk from various beam projections in children undergoing cardiac interventions. The dose area product (DAP) was measured for eleven patent ductus arteriosus device closures (PDA), four atrial septal defect device closures (ASD), and three balloon pulmonary valvuloplasty (BPV) interventions performed using a flat detector system. The total mean DAPs for PDA, ASD and BPV were 1.9 Gycm2, 9.8 Gycm2 and 6.2 Gycm2 respectively. The fluoroscopic kerma dose rates increased by 10%, 33% and 92% when changing the projection from posterior-anterior to lateral projection for PDA interventions among infants, <5 yrs and >5 yrs respectively. The effective dose (ED) and organ doses were estimated from DAP using Monte Carlo software. Lungs received the highest organ dose of 7.4 mGy (PDA), 20.7 mGy (ASD) and 17.3 mGy (BPV) compared to other organs. The mean EDs from PDA, ASD and BPV were 2.5 mSv, 6.1 mSv and 4.9 mSv respectively. PDA intervention performed in infants had a radiation risk 66% higher than children aged between 3-10 years. Their lifetime attributable risk as per BEIR VII for cancer incidence was 1 in 907 males and 1 in 1047 females.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Doses de Radiação , Radiografia Intervencionista , Radiometria/métodos , Criança , Pré-Escolar , Feminino , Fluoroscopia , Humanos , Lactente , Masculino , Método de Monte Carlo , Órgãos em Risco , Estudos Prospectivos , Risco
8.
Pol J Radiol ; 82: 706-712, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29657637

RESUMO

BACKGROUND: Assessment of bone graft substitute incorporation is critical in the clinical decision making process and requires special investigations. We examined if the pixel value ratio (PVR) obtained in routine follow-up digital radiographs could be used for such assessment. MATERIAL/METHODS: Radiographic images were acquired using either computed radiography or flat panel digital radiography systems. The PVR from radiographs of thirty children with ceramic bone substitute grafting were analyzed using the software from the picture archival and communication system (PACS) workstation. Graft incorporation was also assessed using the van Hemert scale. Three independent observers (A, B, C) measured PVRs at two different time points during the first and the last follow-up visits. PVR was compared with the van Hemert scale scores and analyzed using Spearman's rank correlation. RESULTS: The mean intra-observer reliability was 0.8996, and inter-observer reliabilities were 0.69 (A vs. C), 0.78 (A vs. B), and 0.85 (B vs. C) for the first follow-up visit and 0.74 (A vs. C), 0.82 (A vs. B), and 0.70 (B vs. C) for the last follow-up measurements. Spearman's correlation showed a strong negative association between PVR values and van Hemert scale scores, as the healing process advanced on serial measurements at each follow-up (r=-0.94, n=60, z=-7.24, p≤0.0001). The reliability of the PVR measurements was assessed using an aluminum step wedge and ceramic graft. CONCLUSIONS: PVR is potentially a reliable indicator of bone graft incorporation and can aid in clinical decision making provided standard radiographic techniques are used.

9.
J Appl Clin Med Phys ; 17(3): 433-441, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167263

RESUMO

Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing and noise reduction techniques. Real-time monitoring of radiation doses using kerma-area product (KAP) meter was performed for 140 patients using Philips Clarity FD system. The CA procedure involved seven standard projections, of which five were extensively selected by interventionalists. Mean fluoroscopic time (FT), KAP, and reference air kerma (Ka,r) for CA procedure were 3.24 min (0.5-10.51), 13.99Gycm2 (4.02-37.6), and 231.43 mGy (73.8-622.15), respectively. Effective dose calculated using Monte Carlo-based PCXMC software was found to be 4.9mSv. Left anterior oblique (LAO) 45° projection contributed the highest radiation dose (28%) of the overall KAP. Radiation-induced risk was found to be higher in females compared to males with increased risk of lung cancer. An increase of 10%-15% in radiation dose was observed when one or more additional projections were adopted along with the seven standard projections. A 14% reduction of radiation dose was achieved from novel FD system when low-dose protocol during fluoroscopy and medium-dose protocol during cine acquisitions were adopted, compared to medium-dose protocol.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Fluoroscopia/métodos , Órgãos em Risco/efeitos da radiação , Monitoramento de Radiação/instrumentação , Feminino , Humanos , Masculino , Doses de Radiação , Radiografia Intervencionista
10.
J Med Phys ; 40(1): 24-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26150684

RESUMO

Flat panel detector (FPD) technology in interventional cardiology is on the increase due to its varied advantages compared to the conventional image intensifier (II) systems. It is not clear whether FPD imparts lower radiation doses compared to II systems though a few studies support this finding. This study intends to compare radiation doses from II and FPD systems for coronaryangiography (CAG) and Percutaneous Transluminal Coronary Angioplasty (PTCA) performed in a tertiary referral center. Radiation doses were measured using dose area product (DAP) meter from patients who underwent CAG (n = 222) and PTCA (n = 75) performed using FPD angiography system. The DAP values from FPD were compared with earlier reported data using II systems from the same referral center where the study was conducted. The mean DAP values from FPD system for CAG and PTCA were 24.35 and 63.64 Gycm(2) and those from II system were 27.71 and 65.44 Gycm(2). Transition from II to FPD system requires stringent dose optimization strategies right from the initial period of installation.

11.
MAGMA ; 27(5): 397-405, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24306514

RESUMO

OBJECTS: Hepatic and pancreatic fat content become increasingly important for phenotyping of individuals with metabolic diseases. This study aimed to (1) evaluate hepatic fat fractions (HFF) and pancreatic fat fractions (PFF) using (1)H magnetic resonance spectroscopy (MRS) and the recently introduced fast mDixon method, and to examine body fat effects on HFF and PFF, (2) investigate regional differences in HFF and PFF by mDixon. MATERIALS AND METHODS: HFF and PFF were quantified by mDixon with two flexible echo times and by single voxel (1)H MRS in 24 healthy subjects. The regional differences of PFF within the pancreas were assessed with mDixon. Abdominal visceral and subcutaneous fat was assessed by T1-weighted MRI at 3T. RESULTS: Both methods correlated well for quantification of HFF (r = 0.98, p < 0.0001) and PFF (r = 0.80, p < 0.0001). However, mDixon showed a higher low limit in HFF and PFF. PFF showed no regional differences using mDixon. In addition, both visceral and subcutaneous fat correlated with pancreatic fat, while only visceral fat correlated with liver fat, employing both (1)H MRS and mDixon. CONCLUSION: The novel and fast two-point mDixon exhibits a good correlation with the gold-standard (1)H MRS for assessment of HFF and PFF, with limited sensitivity for assessing lower fat content.


Assuntos
Tecido Adiposo/anatomia & histologia , Fígado/anatomia & histologia , Espectroscopia de Ressonância Magnética/métodos , Pâncreas/anatomia & histologia , Gordura Abdominal/anatomia & histologia , Feminino , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Gordura Subcutânea/anatomia & histologia , Imagem Corporal Total
12.
J Med Phys ; 36(1): 40-5, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21430858

RESUMO

Radiation safety in computed tomography (CT) scanners is of concern due its widespread use in the field of radiological imaging. This study intends to evaluate radiation doses imparted to patients undergoing thorax, abdomen and pelvic CT examinations and formulate regional diagnostic reference levels (DRL) in Tamil Nadu, South India. In-site CT dose measurement was performed in 127 CT scanners in Tamil Nadu for a period of 2 years as a part of the Atomic Energy Regulatory Board (AERB)-funded project. Out of the 127 CT scanners,13 were conventional; 53 single-slice helical scanners (SSHS); 44 multislice CT (MSCT) scanners; and 17 refurbished scanners. CT dose index (CTDI) was measured using a 32-cm polymethyl methacrylate (PMMA)-body phantom in each CT scanner. Dose length product (DLP) for different anatomical regions was generated using CTDI values. The regional DRLs for thorax, abdomen and pelvis examinations were 557, 521 and 294 mGy cm, respectively. The mean effective dose was estimated using the DLP values and was found to be 8.04, 6.69 and 4.79 mSv for thorax, abdomen and pelvic CT examinations, respectively. The establishment of DRLs in this study is the first step towards optimization of CT doses in the Indian context.

13.
Indian J Radiol Imaging ; 21(1): 13-4, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21431025

RESUMO

The transjugular intrahepatic portosystemic shunt (TIPS) procedure for decompression of the portal venous system generally performed under fluoroscopic guidance has undergone continuous technical modifications recently. Due to the length of the procedure, the fluoroscopy times are reasonably high, thus increasing the risk from ionizing radiation. Radiation doses were measured for 19 patients using dose area product (DAP) meter. The average DAP value for the TIPS procedure was 63.86 Gy cm(2) (21.12-117.07). Radiation doses to patients can be reduced with the use of USG guidance and intermittent fluoroscopy screening.

14.
Indian J Radiol Imaging ; 20(2): 154-7, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20607033

RESUMO

OBJECTIVE: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. MATERIALS AND METHODS: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tube potential of 140 kV; mAs values were automatically selected by the machine. Effective doses were calculated using dose-length product (DLP) values and the image quality was assessed using the signal-to-noise (SNR) ratio values. RESULTS: Mean effective doses using manual protocol for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 8.58 mSv, 8.54 mSv, and 9.07 mSv, respectively. Mean effective doses using z-axis dose modulation for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 4.95 mSv, 6.87 mSv, and 10.24 mSv, respectively. The SNR at the region of the liver for patients of body weight of 40-60 kg was 5.1 H, 6.2 H, and 8.8 H for manual, angular, and z-axis dose modulation, respectively. CONCLUSION: Dose reduction of up to 15% was achieved using angular dose modulation and of up to 42% using z-axis dose modulation, with acceptable diagnostic image quality compared to the manual protocol.

15.
Radiat Prot Dosimetry ; 136(3): 222-7, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19687133

RESUMO

This study intends to evaluate the current level of computed tomography (CT) scanner doses installed in a region in India. In-site CT dose measurement was performed for 127 CT scanners in a region in India. CT dose index (CTDI) was measured using a 10 cm3 pencil ion chamber and 32-cm polymethyl methacrylate body phantom. The CT numbers and image noise were measured for the phantom using software available on each CT scanner. Of the 127 CT scanners, 13 were conventional, 53 helical single-section, 44 multidetector row CT (MDCT) and 17 refurbished machines. The mean-weighted CTDI (CTDI(w)) values calculated using standard exposure parameters for conventional, conventional refurbished, single-section helical scanner (SSHS), refurbished SSHS and MDCT scanners were 7.5, 6.53, 6.8, 6.6 and 7.04 mGy. Twenty-seven CT scanners had deranged CT numbers. Periodic quality assurance and regional dose surveys would be beneficial to set up regional reference levels in India.


Assuntos
Carga Corporal (Radioterapia) , Radiometria/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Coleta de Dados , Humanos , Índia/epidemiologia , Doses de Radiação
16.
J Med Phys ; 34(4): 217-22, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20098552

RESUMO

Computed tomography (CT) of the abdomen contributes a substantial amount of man-made radiation dose to patients and use of this modality is on the increase. This study intends to compare radiation dose and image quality using dose modulation techniques and weight- based protocol exposure parameters for biphasic abdominal CT. Using a six-slice CT scanner, a prospective study of 426 patients who underwent abdominal CT examinations was performed. Constant tube potentials of 90 kV and 120 kV were used for all arterial and portal venous phase respectively. The tube current-time product for weight-based protocol was optimized according to patient's body weight; this was automatically selected in dose modulations. The effective dose using weight-based protocol, angular and z-axis dose modulation was 11.3 mSv, 9.5 mSv and 8.2 mSv respectively for the patient's body weight ranging from 40 to 60 kg. For patients of body weights ranging 60 to 80 kg, the effective doses were 13.2 mSv, 11.2 mSv and 10.6 mSv respectively. The use of dose modulation technique resulted in a reduction of 16 to 28% in radiation dose with acceptable diagnostic accuracy in comparison to the use of weight-based protocol settings.

17.
Indian J Med Sci ; 61(2): 83-90, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17259687

RESUMO

BACKGROUND: There is widespread concern about radiation doses imparted to patients during cardiology procedures in the medical community. The current study intends to audit and optimize radiation dose to patients undergoing coronary angiography (CA) performed using two dedicated cardiovascular machines. MATERIALS AND METHODS: One hundred and forty nine patients who underwent CA are reported in this study. Dose auditing was done by implementing dose reduction strategies using spectral filters and by evaluating work practices of operators involved in performing CA. STATISTICAL ANALYSIS: A Student's 't' test was used to analyze the statistical significance. RESULTS AND CONCLUSION: The radiation dose imparted to patients was measured using dose area product (DAP) meter. The mean DAP values during CA before optimization was 55.86 Gy cm2 and after optimization was 27.71 Gy cm2. No ill-effects of radiation were reported for patients who underwent CA. Use of copper filtration may be recommended for procedures performed using cardiovascular machines.


Assuntos
Angiografia Coronária/métodos , Fluoroscopia/métodos , Proteção Radiológica/métodos , Adulto , Idoso , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Monitoramento de Radiação , Eficiência Biológica Relativa
18.
J Med Phys ; 32(4): 145-9, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21224923

RESUMO

The percutaneous transluminal coronary angioplasty (PTCA) is one of the interventional procedures which impart high radiation doses to patients compared to the other cardiologic procedures. This study intends to audit and optimize radiation dose imparted to patients undergoing PTCA. Forty-four patients who underwent PTCA involving single or multiple stent placement guided under cardiovascular X-ray machine were included in the study. Radiation doses were measured using dose area product (DAP) meter for patients undergoing single and multiple stent placements during PTCA. A dose reduction of 27-47% was achieved using copper filters and optimal exposure parameters. The mean DAP values before optimization were 66.16 and 122.68 Gy cm(2) for single and multiple stent placement respectively. These values were 48.67 and 65.44 Gy cm(2) respectively after optimization. In the present scenario, due to the increase in the number of PTCAs performed and the associated risk from radiation, periodical audit of radiation doses for interventional procedures are recommended.

19.
J Radiol Prot ; 26(4): 397-404, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17146124

RESUMO

Radiation doses to patients during cardiological procedures are of concern in the present day scenario. This study was intended to audit the radiation dose imparted to patients during the balloon mitral valvuloplasty (BMV) procedure. Thirty seven patients who underwent the BMV procedure performed using two dedicated cardiovascular machines were included in the study. The radiation doses imparted to patients were measured using a dose area product (DAP) meter. The mean DAP value for patients who underwent the BMV procedure from one machine was 19.16 Gy cm(2) and from the other was 21.19 Gy cm(2). Optimisation of exposure parameters and radiation doses was possible for one machine with the use of appropriate copper filters and optimised exposure parameters, and the mean DAP value after optimisation was 9.36 Gy cm(2).


Assuntos
Cateterismo , Fluoroscopia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Proteção Radiológica/métodos , Medição de Risco/métodos , Adulto , Carga Corporal (Radioterapia) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Eficiência Biológica Relativa , Fatores de Risco
20.
Indian J Med Sci ; 59(12): 527-33, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16385171

RESUMO

BACKGROUND: Abdominal embolization procedures performed using digital subtraction angiography (DSA) is on the increase in the present-day scenario owing to their diagnostic and therapeutic values. These procedures involve prolonged fluoroscopy times and may tend to impart high radiation dose to patients if adequate radiation safety measures are not taken. AIM: To evaluate radiation dose imparted to patients and the work practices involved therein during abdominal embolization procedures. MATERIALS AND METHODS: Forty-two patients who underwent abdominal embolizations performed using DSA equipment were included in the study. Dose area product (DAP) was measured using DAP meter and values obtained were used for calculating entrance surface dose (ESD). Work practices of personnel involved in conducting the procedure were evaluated based on the choice of field sizes, selection of appropriate fluoro-modes, and optimization techniques. RESULTS AND CONCLUSIONS: The mean ESD values during hepatic embolization, renal embolization, splenic artery embolization and transarterial chemoembolization (TACE) were 1.2, 1.01, 1.19, and 1.03, respectively. No deterministic effects of radiation, such as transient or main erythema, were noticed for a few patients whose doses exceeded the threshold doses.


Assuntos
Abdome , Embolização Terapêutica , Doses de Radiação , Radiografia Intervencionista , Pele/efeitos da radiação , Angiografia Digital , Quimioembolização Terapêutica , Feminino , Fluoroscopia , Humanos , Masculino , Monitoramento de Radiação/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...